HP (100-200KVA)                     
                     HP (100-200KVA) 
                    
Specifications
                        • Intelligent Battery Management 
• Double Conversion Online Technology
• Load Bus Synchronization (LBS) Function To Protect Your Investment
• Advanced IGBT Rectifier To Have Low THDi and High PF
• Provide LCD Indication and Audible Alarm Function
• Front Accessible Module Design For Ease Of Maintenance
• Wide Input Voltage Range 
• Flexibility Of Configurable Battery Quantity
• Parallel Redundancy 
• Surge, Short Circuit and Overload Protection
• Low Audible Noise 
• Low Output Voltage
• Cold Start 
• ECO Mode
                    
                                                    | Output | : | 
| Phase | 3 Phase 4 Wire (3ph+N) | 
| Rated Voltage | 380 / 400 / 415VAC | 
| Power Factor | 0.8 | 
| Frequency | 50Hz/60Hz ±0.5Hz (Battery Mode) | 
| Voltage Regulation | Balanced Load:±1.0% | 
| THD | Linear Load: 2.0% | 
| Overload Capability | 110% for 60mins | 
| Crest Factor | 03:01:00 | 
| Waveform | Sinusoidal Wave | 
| DC Component | 500mVDC | 
| Output Current | 121A / 145A / 194A / 242A (380V - Full Load) 116A / 139A / 186A / 232A (400V - Full Load) 111A / 133A / 178A / 222A (415V - Full Load) | 
| Input | : | 
| Current Limit | 280A | 
| Rated Voltage | 380 / 400 / 415VAC | 
| Voltage Range | Load50%: 208±5VAC~478±5VAC Load50%: 304±5VAC~478±5VAC | 
| Frequency | 40±0.5Hz~70±0.5Hz | 
| Input Phase | 3 Phase 4 Wire (3ph+N) | 
| THDi | Input THD1.0%, Linear Load: 3.0% Input THD1.0%, Non-Linear Load: 7.0% | 
| Power Factor | >0.99 | 
| Model | Hi3310 / Hi3312 / Hi3316 / Hi3320 | 
| Capacity | 100KVA / 120KVA / 160KVA / 200KVA | 
| System | : | 
| Efficiency | 90% (AC Mode) 93% (Battery Mode) 97% (ECO Mode) | 
| Wasting | 3% (AC Mode) 2% (ECO Mode) | 
| Noise at 1M | <62dB (100/120KVA) <65dB (160/200KVA) | 
| Temperature | 0~40ËšC | 
| Humidity | 0%RH~95%RH (Non-condensing) | 
| Altitude | <1000m | 
| Display | LCD+LED | 
| Air Switch/ Fuse | 225A (100/120KVA) 315A (160/200KVA) | 
| Remote Signaling | Dry Contact | 
| Communication | RS232/RS485/SNMP | 
| MTBF | Inverter MTBF >50,000 Hours Single UPS MTBF >250,000 Hours 1+1 Parallel System MTBF >400,000 Hours | 
| MTTR | Single UPS MTTR <30mins | 
| Insulation Resistance | > 2MΩ (500VDC) | 
| Dielectric Strength | 2820VDC, No ARC in 1min | 
| Lightning Protection | 6000V/3000A | 
| Shock and Vibration | ISTA (International Safe Transmission Association) 1B | 
| Shipment | ISTA (International Safe Transmission Association) 1B | 
| Degree Of Protection | Ip20 | 
| Net/Gross Weight (kg) | 295/363, 590/720 | 
| Dimension(WxDxH) mm | 100/120KVA 160/200KVA 600 x 730 x 1800 1200 x 730 x 1800 | 
| Packaging(WxDxH) mm | 100/120KVA 160/200KVA 735 x 845 x 1990 1335 x 845 x 1990 | 
| Bypass | : | 
| Voltage Range | 380V 208/266/304±5VAC~399/418/437/475±5VAC 400V 220/280/320±5VAC~420/440/460±5VAC 415V 228/290/332±5VAC~436/457/477±5VAC | 
| Frequency Range | 50Hz±10% / 60Hz±10% | 
| Phase | 3 Phase 4 Wire (3ph+N) | 
| Overload Capability | 125%~170% for 10mins | 
| Eco Mode | : | 
| Voltage Range | 380V 304±5VAC~399 / 418±5VAC 400V 320±5VAC~420 / 440±5VAC 415V 332±5VAC~436 / 457±5VAC | 
| Frequency Range | 50Hz±10% / 60Hz±10% | 
| Phase | 3 Phase 4 Wire (3p+N) | 
| Battery | : | 
| Model | Sealed Lead Acid Maintenance Free (VRLA) | 
| Configurable Battery | 32 / 34 / 36 / 38 / 40 pcs | 
| Discharge Current(320VDC) | 270A (100/120KVA) 430A (160/200KVA) | 
| Charge Current(Max) | 30A (100/120KVA) 60A (160/200KVA) | 