MH-1500                     
                     MH-1500 
                    
Overview
- Cold start
- Super powerful charger built-in
- Overload protection
- Fully digitized microprocessor control LED
- Short circuit protection
- Energy saving function with UPS green mode
- Wide input voltage range
- Intelligent longer backup series
Specifications
| Input | : | 
| Nominal Voltage | 220VAC | 
| Voltage Range | MH 600~MH 1500 Inverter mode: 90V~270V, UPS mode: 135V~270V MH 2000~MH 5000 Inverter mode: 90V~270V 2KVA/3KVA: 160V~265V for 4KVA/5KVA UPS mode: 135V-270V 2KVA/3KVA: 190V-260V for 4KVA / 5KVA | 
| Phase | Single phase & Ground | 
| Frequency | 38-70Hz | 
| Generator Input | Support | 
| Output | : | 
| Voltage Range | MH 600~MH 1500 Inverter mode: 90V-270V UPS mode: 190V-260V Battery mode: 220v±10% MH 2000~MH 5000 Inverter mode: 90V-270V UPS mode: 190V-260V Battery mode: 220V±10% | 
| Frequency | MH 600~MH 1500 Utility mode: Same as utility, Battery mode: 50Hz±1Hz MH 2000~MH 5000 Utility mode: Same as utility Battery mode: 50Hz±1Hz | 
| Waveform | MH 600~MH1500 Utility mode: Tracking utility Battery mode: Sinewave MH 2000~MH 5000 Utility mode: Tracking utility Battery mode: Sinewave | 
| Power Factor | 0.8 | 
| Transfer Time | 6ms | 
| Model/Capacity | MH 1500: 1500VA/1200W | 
| Battery | : | 
| Voltage | MH 1500: 24VDC | 
| Recharge Voltage | MH 15000: 27.6 ±0.6V | 
| Recharge Current | MH 1500: 10/20A | 
| AC Mode | 1. Load<100%, Working normally 2. Load<100%~120%, shut down after 3 mins and then restart automatically after 30 secs 3. Load<120%~130%, overload, shut down after 30 secs and then restart automatically after 30 secs 4. Load<130%, overload, will shut down immediately and then restart automatically after 30 secs *After repetitive 3 times, if overload remains, transfer to fault mode, needs restart manually | 
| Battery Mode | 1. Load<100%,Working normally 2. Load<100%~110%, Overload, shut down after 10 secs and then restart automatically after 30 secs 3. Load<110%, overload, will shut down immediately and then restart automatically after 30 secs *After repeat 3 times, if over-load remains, transfer to fault mode, needs restart manually | 
| Physical | : | 
| Dimensions (WxDxH) (mm) | 300 x 252 x 163 | 
| Packaging (WxDxH) (mm) | 420 x 384 x 275 | 
| Weight (kgs) | 17.6 | 